Technical Specifications
GANGA Roofing, wall cladding, tile, corrugation and accessories are manufactured from the finest high quality raw material coils of PPGI (Pre Painted Galvanized Iron), PPGL (Pre Painted Galvalume) and NCGL (Non Colour Galvalume).
Structure of Pre-painted Steel Sheet
 
Material Specifications Material Specifications
PPGL ( Pre Painted Galvalume
Alu Zinc coating ) GL Base

PPGI (Pre Painted Galvanized Iron) GI Base
Thickness :   0.35mm~0.60mm
Alu-Zinc coating :   AZ150 Standard. AZ100, AZ70 and
    higher Alu-Zinc coatings optional
Coil width :  1170mm
Sheet width :  1060mm
Effective width :  1000mm
Tensile strength :  550 Mpa Standard.245~400 Mpa    optional
Standards met :  ASTM A755,JIS 3322, AS1397,IS277
Paint :  RegularModifiedPaint(RMP)Standard.   Optional- Silicon Modified Polyester   (SMP)&PVF2
Colours
:  6 Standard Optional-wide range
   including RAL codes
Thickness :   0.35mm~0.60mm
Zinc coating :   Z120 Standard. Z100 and higher Zinc     coatings optional
Coil width :  1170mm
Sheet width :  1060mm
Effective width :  1000mm
Tensile
strength
:  245~345 Mpa Standard.
Standards met :  ASTM A653, JIS 3312, IS277,AS 1397
Paint :  RegularModifiedPaint(RMP)Standard.   Optional- Silicon Modified Polyester   (SMP)&PVF2
Colours
:  6 Standard Optional-wide range
   including RAL codes
 
Material Specifications
NCGL ( Non Colour Galvalume or Bare Galvalume Alu Zinc coating ) GL Base
Thickness :   0.40mm~0.60mm
Alu -Zinc coating :   AZ100, 90,AZ70 and  higher Alu-Zinc coatings optional
Coil width :  1145 mm / 1170 mm
Sheet width :  1060 mm
Effective width :  1000 mm
Tensile strength :  Standard 245~345 Mpa  optional
Standards met :  ASTM A792,AS 2728, IS277
   
Trapezoidal Roofing Load Chart
Note :
DLLL Dead Load + Live Load (Deflection Limitation : Span/180)
UDL-Wind Uniform Distributed Load - Wind (Deflection Limitation Span/120)Material Conforming to ASTM 792 Grade 80 (Yield Strength 550mpa) or equivalent
Alllowable Uniform Load Kg / m2
Sheet TK
mm
LoadCase
Purlin Spacing Meter
1.0
1.1
1.2
1.3
1.4
1.5
1.6
1.7
1.8
1.9
2.0
0.35
udi - DLLL
306.4
230.2
177.3
139.5
111.7
90.8
74.8
62.4
52.5
44.7
38.3
udi - wind
574.6
431.7
332.5
261.5
209.4
170.2
140.3
116.9
98.5
83.8
71.8
0.4
udi - DLLL
395.7
297.3
229
180.1
144.2
117.2
96.6
80.5
67.8
57.7
49.5
udi - wind
741.8
557.4
429.3
337.7
270.4
219.8
181.1
151
127.2
108.2
92.7
0.47
udi - DLLL
521.6
391.9
301.9
237.4
190.1
154.6
127.4
106.2
89.4
76.1
65.2
udi - wind
978.1
734.8
566
445.2
356.4
289.8
238.8
199.1
167.7
142.6
122.3
0.5
udi - DLLL
574.4
432.3
333
261.9
209.7
170.5
140.5
117.1
98.7
83.9
71.9
udi - wind
1078.9
810.6
624.4
491.1
393.2
319.7
263.4
219.4
185
157.3
134.9
0.6
udi - DLLL
736.8
553.6
426.4
335.4
268.5
218.3
179.9
150
126.3
107.4
92.1
udi - wind
1381.6
1038
799.5
628.8
503.5
409.4
337.3
281.2
236.9
201.4
172.7
 
SAFE HANDLING , INSTALLATION AND MAINTENANCE
 
Durability & Safety
Design & Flexibility
Superior Technology
Environment Friendly
 
Packing, Storage and Handling : Keep the product dry and clear off the ground on wooden blocks. Do not slide the sheet over rough surface. If sheets are wet, wipe with clean cloth. Roofing & Cladding sheets should be erected as soon as possible on arrival at the job site. In case of temporary storage, the same should be stored in-doors. In case of outdoor storage, the sheets have to be covered with tarpaulin.
Walking on roof : Walk on the valley of the roof thus keeping your weight evenly distributed.
For cutting the sheets, the usage of knibbler is recommended. The cut materials and metal particles are required to be swept from the ground. Failure to do so will lead to rusting or surface staining.
Fixing of SDS screws recommended with Torque adjustable guns. For roof work, fix screws on the crest. For wall cladding, fix on the crest or on the valley. Fasteners to confirm to AS 3566 Class 3 - 4 for external application.
 
 
   
 
 